NX-3060-G6 System Specifications. System Specifications. You can use it to provision Windows or Linux desktops on prem (on Nutanix AHV) or on any major public cloud (like Azure, AWS, or GCP). Check part details, parametric & specs updated 03 NOV 2023 and download pdf datasheet from datasheets. Controls and LEDs for Multinode Platforms. Check part details, parametric & specs updated 14 AUG 2023 and download pdf datasheet from datasheets. NX-8035-G8: 1: YES: YES: 2: No: YES: NX-8150-G8: 1: NO: YES: NX-8155-G8: 1: For CPUs with a thermal design profile equal to or less than 130 W: redundant at 110 V over the entire supported ambient temperature range of 10° C to 35° C. 2 RAID1. NX-8035-G7. Download PDF. in the servers, network servers category. For all other CPUs, use the following rule: Ambient temperature is 25° C or less: YES. Please login to access the full list of documentation. Yes. After submitting your request, a representative will respond to you within 24 hours with your pricing and additional information you may need to make your purchase. Local: 949-328-2860 Toll Free: 866-981-2998 Sales@WebScaleWorks. Currently viewing public documentation. Is it possible to add three NX-8135-G8 nodes to a cluster created with three SX-1065-G5 nodes? In the document about “Product Mixing Restrictions”, there is no mention of NX and SX hardware model mixing information. 46" (88 mm) Width: 17. The Nutanix virtual computing platform delivers the power and simplicity of web-scale infrastructure as a turnkey solution to enterprise customers. 2 x 512GB M. 8 ghz/ 8-core/ 105w ice lake) per node. Nutanix simplifies datacenter infrastructure by integrating server and storage resources into a turnkey appliance that is deployed in just 30 to 60 minutes, and runs any application at any scale. The primary difference between these two platforms, and their nodes, is the supported networking configurations. NX-3060-G6 platforms have one, two, three, or four nodes per block. Conditions Description Operational Impact Remarks UCR Waivers None TDR # Conditions of Fielding None (Table continues next page. Best practice is generally to use the latest BIOS version available for the server, even if it is newer than listed. Modernize Your Datacenter. Platforms include industry standard x86 server models on which Nutanix software. 2 GHz] Gold 6128 [6 コア/ 3. Nutanix NX-8155N-G8. Check part details, parametric & specs updated 04 OCT 2023 and download pdf datasheet from datasheets. X-Ray. com, a global distributor of electronics. Rear view shapes for NX-8035-G7 & NX-8035-G6 share the same. com, a global distributor of electronics components. 1 GHz] €€€€€Gold 6248 [20 cores / 2. Overview: Nutanix Frame is a cloud-hosted Desktop as a Service (DaaS) that empowers any organization to deliver and manage their desktops via a single console for seamless control and administration, providing a true hybrid experience. You can mix DIMMs from different. 5, compliance is maintained for other versions of the respective operational environments where the module binary is unchanged. 32 GB, 64 GB:field installation. This document covers the NX-8035N-G8 specifications. Engineering Tools. A 2U NX-6000 includes 32 cores, 32 TB of hard drive capacity and either 1. - Nutanix has added their NX-1175s-G8 and NX-8035-G8: 08-Mar-2022 - Another HPE Update - HPE has added new Aruba switches, the ProLiant DL20 Gen10 Plus and ProLiant ML30 Gen10 Plus:. For all other CPUs, use the following rule: • Ambient temperature is 25° C or less: YES • Ambient temperature is. Nutanix is targeting to fix this bug in the next NCC major release. . Node Naming (SX-1065-G5) SX-1065-G5 System Specifications. Go beyond hyperconverged infrastructure and get hands-on experience with the Enterprise Cloud Platform that powers the world's largest datacenters. The NX-3060-G8 supports solid-state drives (SSD) and non-volatile memory express drives (NVMe). NX-8035-G5 X10DRT [Haswell]: NX-1065-G4 NX-3060-G4 NX-6035-G4 NX-8035-G4 NX-9060-G4: BIOS G4G5T8. 1 ghz, 16 cores, cascade lake). NVMe drives, if used, must always be placed in the last four drive slots on the right. The single-socket NX-1175S-G8 platform contains only one DIMM slot per channel, so mixing DIMMs in the same channel is not possible. NX-8035-G8. They offer a streamlined IT operations (ITOps) experience for all your workloads from day-0 through day-n. 92 TB], 2x HDD: [2 TB, 4 TB, 6 TB] 2x M. Node A. . NX-8035-G5. 32 gb, 64 gb: 32 gb, 64 gb, 128 gb: 12 : cpu1: a1, b1, c1, e1, f1, g1 . These are not the only supported or recommended configurations. Check part details, parametric & specs updated 03 NOV 2023 and download pdf datasheet from datasheets. Check part details, parametric & specs updated 14 AUG 2023 and download pdf datasheet from datasheets. Learn more about the system specifications, features, and benefits of the NX-1065-G4 and how it compares with other Nutanix hardware platforms. 2 GHz] Silver 4116 [12 コア/ 2. 4309Y, 4310T,4314 and 4310 do not support 128GB memory option. tvuongpham. DISA Memo, IE, DoDIN APL Approval Memo, Nutanix Acropolis Rel. Nutanix's NX-8235-G7-6252-CM is a 2 node with intel xeon processor 6252 (2. 20-Oct-2015. The NX-8035N-G8 platform is the naming convention for a specific type of node configuration and is also a refresh to the NX-8035-G8 platform. NX platforms include 1-node and multi-node systems for entry-level deployments, balanced. Please help. - Nutanix has added their new NX G8 Series product stencil: 23-Jan-2022 - DataCore Update! - DataCore has just released a huge update of Visio stencils for. Nutanix's NX-3160-G7-4210-CM is a 1 node with intel xeon processor 4210 (2. 1 GHz] Gold 5120 [14 コア/ 2. Nutanix NX-1065-G8. The Enterprise Cloud delivers a consistent, high-performance and seamless experience for both cloud operators and consumers of cloud-delivered. Best practice is generally to use the latest BIOS version available for the server, even if it is newer than listed. Node Naming (NX-8035-G6) NX-8035-G6 System Specifications. For all other CPUs, use the following rule: Ambient temperature is 25° C or less: YES. For the releases that have had extensions, the dates in the table are inclusive. cpu2: a1, e1. Maximum measurements are shown. com, a global distributor of electronics components. com, a global distributor of electronics components. 32 gb, 64 gb: 32 gb, 64 gb, 128 gb: 16: fill all blue slots. This document covers the NX-8035N-G8 specifications. Download PDF. 9 GHz (48 cores per node) 2 x Intel Xeon Gold_6248R, 24-core Cascade Lake @ 3 GHz (48 cores per node)NX-8035-G7. A non-critical loss of use with medium to low impact. Maximum measurements are shown. Did the default password change with the release. BlueAlly services are offered throughout the United States. Model Supported BMC Firmware; X11DPT-B, DPU, SPW [Skylake]: NX-1065-G6 NX-1175S-G6 NX-3060-G6 NX-3170-G6 NX-3155G-G6 NX-5155-G6 NX-8035-G6 NX-8155-G6: Use KB 7812 for upgrading to BMC-7. Once the servers are whitelisted inside the Prism management interface, the LUNs are discovered through the iSCSI discovery. Currently viewing public documentation. NX-8035-G8; NX-8035N-G8; NX-8150-G8; NX-8150N-G8; NX-8155-G8; NX-8155N-G8; NX-8170-G8; NX-8170N-G8; Software Editions; Legacy Products. drawing and stencil for Nutanix NX-3175-G4 model. in the servers, network servers category. Menu. Standardize on powerful and secure hyperconverged infrastructure to deliver all applications and data at any scale, on any cloud. 4 GHz]Nutanix NX-8035N-G8. Nutanix Hybrid Cloud Software on Industry-Standard Servers. Platforms include industry standard x86 server models on which Nutanix software can be installed. I am having some trouble performing the initial configuration and wondering if I could get some support as I am stuck. Nutanix DMI Information. Dual M. For CPUs with a thermal design profile equal to or less than 130 W: redundant at 110 V over the entire supported ambient temperature range of 10° C to 35° C. 6 or later, the NX-8035-G6 also supports non-volatile memory express drives (NVMe). The single-socket NX-1175S-G8 platform contains only one DIMM slot per channel, so mixing DIMMs in the same channel is not possible. Nutanix NX nodes are purpose-built SuperMicro appliances with configuration options for all hyperconverged infrastructure (HCI) use cases. 4 ghz/ 16-core/ 135w ice lake) per node. 3200 MHz is the highest speed Nutanix currently supports, so you cannot currently mix DIMM speeds in any NG8 node. 40 GHz]. Hardware Components; Nodes: 1 to 4 nodes per block: CPU Options: NX-8035-G6. Contact us for Pricing! Get a Quote. Login into Nutanix Support Portal. Dual Intel Ice Lake: Intel Xeon Silver 4310 [12 cores / 2. NX-8035-G8. For all other CPUs, use the following rule: Ambient temperature is 25° C or less: YES. 50° to 95° F (10° to 35° C) Nonoperating temperature. Within 8 hrs (4 hours for Mission Critical Support Program)*. NX-6035-G4 and NX-8035-G4 System Specifications. 01. Compare Intel. Note: Nutanix recommends that you carefully plan your AC power source needs, especially in cases where the cluster consists of mixed models. 32 gb, 64 gb: 32 gb, 64 gb, 128 gb: 8: cpu1: a1, c1, e1, g1 . Please login to access the full list of documentation. Home Storage & Hard Drives Network Attached Storage NUTANIX NX-8035N-G8 1 NODE 2X6348 Mfg. Nutanix Calm adds native application orchestration and lifecycle management to the Nutanix Enterprise Cloud Platform. Single-node platforms. Table 1. Single-node platforms. EUROPEAN REGULATION No. Dual Intel Ice Lake: Intel Xeon Silver 4316 [20 cores / 2. Node Naming (NX-3060-G6) Nutanix assigns a name to each node in a block, which varies by product type. 2 x 512GB M. After submitting your request, a representative will respond to you within 24 hours with your pricing and additional information you may need to make your purchase. NX-1065-G8 NX-3060-G8 and NX-8035-G8; 4: CPU1: A1, E1. Hardware. cpu2: a1, b1, c1, e1, f1, g1. X300M-STX. The NX-8035-G6 supports partial population of drive slots with SSDs (not HDDs. Best practice is generally to use the latest BIOS version available for the server, even if it is newer than listed. Nutanix - NX-8035-G8 Description ENERGY STAR Partner : NX-8035-G8: 1: YES: YES: 2: No: YES: NX-8150-G8: 1: NO: YES: NX-8155-G8: 1: For CPUs with a thermal design profile equal to or less than 130 W: redundant at 110 V. We recently purchased 2 x NX-8235N-G8-CM (total of 4 nodes), which will be explicitly used as storage servers. Collection is compatible with Visio versions 2013 to 2019. 1, 2 or 3 x 10GbE 4P NIC. Nutanix manages storage allocation and assignment for ABS through Volume Groups (VG). A short-term workaround is available. Know your gear. in the memory cards and modules, memory modules category. Get the latest NX-8035N-G8 End of Service Life (EOSL) information from Park Place Technologies, then contact us for a maintenance quote today!. For example, you have a Nutanix block model NX-8035-G5 and you want to know the supported AOS and Hypervisor for the chosen Model. The NX-6050 costs $120,000 for two nodes, while the NX-6070 is priced at $180,000 for two nodes. NX-1065-G4 NX-3060-G4 NX-6035-G4 NX-8035-G4 NX-9060-G4: BIOS G4G5T8. Contact us for Pricing! Get a Quote. 2 x 240GB M. Unify All Your Clouds. Table 1. Nutanix - NX-8035-G8 Description ENERGY STAR Partner :NX-8035-G8: 1: YES: YES: 2: No: YES: NX-8150-G8: 1: NO: YES: NX-8155-G8: 1: For CPUs with a thermal design profile equal to or less than 130 W: redundant at 110 V over the entire supported ambient temperature range of 10° C to 35° C. in the servers, network servers category. Nutanix's NX-1175S-G8-4316-CM is a 1x intel xeon- silver 4316 processor (2. 1 ghz, 8 cores, cascade lake). Nutanix NX-3155GN-G8. NX-8035-G8: Notes: This page lists the specific configurations for which the server vendor has submitted certification test results to VMware, including BIOS version. Newer V1 and V2 simplified rail kits for multi-node 2U tall -G6 and -G7 platforms have outer rails that install directly into the rack (For example, NX-1065-G6/G7, NX-3060-G6/G7, NX-8035-G6/ G7). This may include the AOS version, Prism central, Nutanix files or Supported hardware platforms. 4. Hardware & software product recommendations & sales. Yes. This makes it possible to arrive at a total per-user cost top to bottom, removing the need for. Citrix CVAD , VMware Horizon, and Nutanix Frame). How can I determine if these support a TPM 2. Try it for free today! Claranet Drives Innovation with the Nutanix. Print to PDF. The first two SSDs in each node contain the Controller VM (CVM) and metadata. These services are inserted in-line or in tap-mode with VM traffic, and can be easily enabled for all traffic, or deployed only for specific network traffic. CPU2: A1, C1, E1, G1 . Nutanix's NX-8235-G7-6252-CM is a 2 node with intel xeon processor 6252 (2. Slots 11 and 12 are filled with nonremovable thermal management assemblies. Contact us for Pricing! Get a Quote. 32 GB, 64 GB:for P/N: NX-8035-G6; View Tech Specs . NX-8035-G8: 1: YES: YES: 2: No: YES: NX-8150-G8: 1: NO: YES: NX-8155-G8: 1: For CPUs with a thermal design profile equal to or less than 130 W: redundant at 110 V. 6 GHz]Trailblazer. General description The TDA8035 is the cost efficient successor of the established integrated contact smart card reader IC TDA8024. Get configuration recommendations for specific use cases and workloads to optimize your environment. NX-8035N-G8 System Specifications. nutanix. 32 gb, 64 gb: 32 gb, 64 gb, 128 gb: 8: cpu1: a1, c1, e1, g1 . Beam provides organizations with deep visibility and rich analytics detailing cloud consumption patterns, along with one-click cost optimization across their cloud environments. Hardware Components; Nodes: 1 to 4 nodes per block: CPU (All specifications provided for each node unless indicated as a block specification. CPU2: A1, E1. Moustafa Hindawi | Blogger | Nutanix Technology Champion | NCSE | NCM-MCI | VMCE | 2xVCAP-DTM & DCV | 2xVCP-NV & CMA | LinkedIn:. Each node must contain DIMMs only of the same type, speed, and capacity. Maximum measurements are shown. 56. Enterprise ServersDynamic Rear View Shapes for: NX-8035-G7 & NX-8035-G6. 8035: Category: Category BC - Britannia Balcony Stateroom: Description: Britannia Balcony staterooms feature floor-to-ceiling windows with glass doors that open to a private balcony. Note: On NX-3060/1065/8035-G8 platforms, some Memory Temperature may show as 0. The SaaS control plane provides an end-to-end platform that is centrally managed from the cloud through a user-friendly interface for application development and operations to easily deploy thousands of edge locations. Node A; Node B; Node C; Node D; Physical drives are arranged in the chassis according the node order shown below. 65Nutanix assigns a name to each node in a block, which varies by product type. See a complete list of all Nutanix products on insight. Please login to access the full list of documentation. The first drive in each node contains the Controller VM and metadata. 9993 9193. * NXS2U2NL12G800 will cover NX-8135-G8, NX-8135N-G8, NX-8235-G8 and NX-8235N-G8 models and its Options (Part numbers starting with C-), Upgrades (Part numbers starting with U-) and Spares/FRU (Part numbers starting with X-). Nutanix's NX-3460-G8-5317-CM is a 2x intel xeon-gold 5317 processor (3 ghz/ 12-core/ 150w ice lake) per node. Ambient temperature is greater than 25° C: NO. Print to PDF. UpNX-8035-G8: 1: YES: YES: 2: No: YES: NX-8150-G8: 1: NO: YES: NX-8155-G8: 1: For CPUs with a thermal design profile equal to or less than 130 W: redundant at 110 V over the entire supported ambient temperature range of 10° C to 35° C. Please login to access the full list of documentation. com, a global distributor of electronics components. com, a global distributor of electronics components. Nutanix's NX-3360-G7-4208-CM is a 3 nodes with intel xeon processor 4208 (2. Nutanix Hardware Naming Convention. Controls and LEDs for 2U2N Platforms. Note: The manual upgrade procedure is only recommended when LCM is unavailable. - Nutanix has added their new NX G8 Series product stencil: 23-Jan-2022 - DataCore Update! - DataCore has just released a huge update of Visio stencils. Nutanix NX platforms are designed for use in all hyperconverged infrastructure, hybrid and private cloud solutions. They offer a streamlined IT operations (ITOps) experience for all your workloads from day-0 through day-n. 362 TB; Storage Type: All SSD SED, NVMe+SSD, All SSD, SSD+HDD, SSD+HDD SED; Use Case(s): Database and Business Critical Apps, Analytics and Big Data; Learn More The NX-8035N-G8 platform is the naming convention for a specific type of node configuration and is also a refresh to the NX-8035-G8 platform. The NX-8035-G7 supports hard disk drives (HDD), solid-state drives (SSD), and non-volatile memory express drives (NVMe). 1 GHz],drawing and stencil for Nutanix NX-3175-G4 model. Server Compute: Dual Intel Ice Lake; Max Memory: 2048 GB; Max Processor Cores: 32 Cores (per CPU socket) Max Storage Capacity: 87. com; Or by phone: +91 99862 88377Use KB 12447 for upgrading BIOS on G8 platforms Use KB 15172 for upgrading BMC and BIOS on G9 platforms. Get high-levels of availability and resiliency in the event of component failure, node failure, rack failure, or an entire datacenter outage. NX-8035-G6-SSD Visio Stencil-EQID=NUTX095. 72. For. Every Nutanix block has a unique name based on the standard Nutanix naming convention. com; Baskaran – Sales@navigatorsystem. Computer accessories. com to find the technology you need. 2 Boot Device; CPU: Note: Processor models 6342, 6348, 8358, 8360Y, 8380 support a maximum ambient temperature of 30C. 64. NXS2U2NL12G800 *. Nutanix reduces the cost of deploying and operating a private cloud, while satisfying ever-increasing service. 1 ghz, 8 cores, cascade lake). Slots 1 through 10 support NVMe drives. Use KB 12447 for upgrading BIOS on G8 platforms Use KB 15172 for upgrading BMC and BIOS on G9 platforms. NX-8035-G8; NX-8035N-G8; NX-8150-G8; NX-8150N-G8; NX-8155-G8; NX-8155N-G8; NX-8170-G8; NX-8170N-G8; Software Editions; Legacy Products. SX-1065-G5. com, a global distributor of electronics components. Technical Question on upgrade :Customer has existing 1365-G6 cluster nodes. NX-3400-Node Visio Stencil-EQID=NUTX039. Use KB 12447 for upgrading BIOS on G8 platforms Use KB 15172 for upgrading BMC and BIOS on G9 platforms. com, a global distributor of electronics components. 63 kg) Depth (from rear node pull rings to front of bezel): 848 mm (33. Nutanix's NX-1365-G7-4214R-CM is a nx 1365 g7, 3 node with xeon processor 4214r 2. NX-3060-G7 System Specifications. NX-3060-G5 System Specifications. Effortlessly move apps and data between public, private, and edge clouds for a true hybrid multicloud experience. Nutanix software has been designed to integrate with hardware platform configurations produced or certified by Nutanix and OEM partners. . Customers with active service contracts will continue to receive support from the Nutanix support as. 08. Buckets is designed for backup, long term retention/archiving, and cross. Modernize Your Datacenter. 32 GB, 64 GB:Once a product is EOL (end of life), then there will be no further upgrades/updates released for it and will no longer be supported by Nutanix. Mailing Address: WebScaleWorks. Check part details, parametric & specs updated 03 NOV 2023 and download pdf datasheet from datasheets. NX-8035-G8: 1: YES: YES: 2: No: YES: NX-8150-G8: 1: NO: YES: NX-8155-G8: 1: For CPUs with a thermal design profile equal to or less than 130 W: redundant at 110 V over the entire supported ambient temperature range of 10° C to 35° C. Enterprise Applications Virtualize tier 1 workloads with predictable performance and scalability. Physical drives are arranged in the chassis according the node order shown in the following diagrams. Contact us for Pricing! Get a Quote. P4. Node Naming (NX-9060-G4) NX-9060-G4 Series System Specifications. in the servers, network servers category. Width is from ear to ear; depth is from ears to pull rings. Nutanix Support & Insights. The primary difference between these two platforms, and their nodes, is the supported networking configurations. 115 Cary, NC 27518 866-981-2998 Sales@WebScaleWorks. 0 GHz (40 cores per node)Sub-Categories. 11623 10693. Contact us for Pricing! Get a Quote. Gain visibility into your infrastructure through health, availability, and performance insights. Nutanix's NX-1465-G7-4208-CM is a 4 node with intel xeon processor 4208 (2. NX-8235-G7 Switch Port Configuration. - Nutanix has added their NX-1175s-G8 and NX-8035-G8: 08-Mar-2022 - Another HPE Update - HPE has added new Aruba switches, the ProLiant DL20 Gen10 Plus and ProLiant ML30 Gen10 Plus:. com, a global distributor of electronics. Deploy, manage and scale a single software-driven storage platform that spans multiple clouds and datacenters. Flow Networking for AHV virtualization brings virtual private cloud (VPC) and other advanced virtual networking constructs together to bridge traditional and cloud-native network models. ) Any configuration that includes NVMe drives must also include four SSDs, so partial population is not supported for configurations including NVMe. 2 GHz] Storage Capacity HYBRID 1x SSD: [960 GB or 1. There is sitting area with sofa. Of course the customer procures SFP+ modules supported by the switch manufacturer and wants to use those for the Nutanix nodes as well. Check part details, parametric & specs updated 03 NOV 2023 and download pdf datasheet from datasheets. Beam provides organizations with deep visibility and rich analytics detailing cloud consumption patterns, along with one-click cost optimization across their cloud environments. In order to check Nutanix AOS, AHV or 3rd Party Hypervisor Compatibility with certified hardware, you can visit the Nutanix portal and select "Compatibility Matrix". 5, compliance is maintained for other versions of the respective operational environments where the module binary is unchanged. The NX-8035N-G8 platform is the naming convention for a specific type of node configuration and is also a refresh to the NX-8035-G8 platform. (42. Loading. These are not the only supported or recommended configurations. 5799 5335. Node Naming (NX-8035-G8) NX-8035-G8 System Specifications. Self-Service. They offer a streamlined IT operations (ITOps) experience for all your workloads from day-0 through day-n. Nutanix's C-NIC-25GSFP2-A-CM is a 25gbe, 2-port, sfp28 network adapter. Our team is here to help you!NX-8035-G8 . Custom application development. (Per Block) Op Temp Range: 50° to 95°F (10° to 35°C) Non-Op Temp Range: -49° to 158°F (-45° to 70°C) Op Humidity Range (non-condensing): 68° to 194°F (20° to 90°C) Non-Op Humidity Range: 41° to 203°F (5° to 95°C) Power Consumption. Click or touch the Flag. It eliminates the need for network-based storage architecture, such as a storage area network (SAN) or network-attached storage (NAS). Download PDF. Nutanix NX nodes are purpose-built SuperMicro appliances with configuration options for all hyperconverged infrastructure (HCI) use cases. The NX-8035-G8 supports partial population of drive slots with SSDs (not HDDs. 2 RAID1. No claim can be made as toCurrently viewing public documentation. NX-8035-G6. Nutanix NX nodes are purpose-built SuperMicro appliances with configuration options for all hyperconverged infrastructure (HCI) use cases. 0/SATA 3. Chetan Gupta. Converged Server/Storage System. NX-3060-G8 platforms have one, two, three, or four nodes per block. This document covers the NX-8035N-G8 specifications. Nutanix sells a number of versions of its NX HCI nodes targeted at a variety of different use cases and a mixture of configuration options, such as memory, storage and compute. 6 ghz/ 32-core/ 250w ice lake) per node. . That seemed to be a valid choice, until testing the available SFP+. The Nutanix NX-8000 Series Virtual Computing Platform integrates high-performance server resources with enterprise-class storage in a cost-effective 2U appliance. The world’s most advanced enterprise datacenters rely on the Nutanix Xtreme Computing Platform to run their mission-critical workloads. 0/NVMe hot-swap. Nutanix - NX-8035-G8 Description ENERGY STAR Partner : Nutanix Form Factor : Multi-node Resilient System : No Number of Nodes for Multi-node : 2 Operating Systems Supported : Windows,Linux Product Processor Socket Count : 2 Maximum Memory Capacity (GB) : 2048. com, a global distributor of electronics components. 2 Boot Device; CPU: Note: Processor models 6342, 6348. 5 GHz]NX-8035-G8: Notes: This page lists the specific configurations for which the server vendor has submitted certification test results to VMware, including BIOS version. Table 1. Mailing Address: WebScaleWorks. 1 ghz, 24 cores, cascade lake). NX-8035-G8: 1: YES: YES: 2: No: YES: NX-8150-G8: 1: NO: YES: NX-8155-G8: 1: For CPUs with a thermal design profile equal to or less than 130 W: redundant at 110 V over the entire supported ambient temperature range of 10° C to 35° C. 13343 12275. Component Specifications. Check part details, parametric & specs updated 13 AUG 2023 and download pdf datasheet from datasheets. 1 GHz] €€€€€Gold 6248 [20 cores / 2. Interested in learning more about how Park Place can help maximize your. 32 GB, 64 GB:The NX-8035-G8 supports hard disk drives (HDD), solid-state drives (SSD), and non-volatile memory express drives (NVMe). Build an enterprise cloud with hyperconverged compute, storage, virtualization, and networking at the core. Boot Device. This document covers the NX-8035N-G8 specifications. Component Specifications. Nutanix NX nodes are purpose-built SuperMicro appliances with configuration options for all hyperconverged infrastructure (HCI) use cases. * NXS2U2NL12G800 will cover NX-8135-G8, NX-8135N-G8, NX-8235-G8 and NX-8235N-G8 models and its Options (Part numbers starting with C-), Upgrades (Part numbers starting with U-) and Spares/FRU (Part numbers starting with X-). 32 gb, 64 gb: 32 gb, 64 gbNutanix NX-8035-G8. The NX-8035-G7 supports hard disk drives (HDD), solid-state drives (SSD), and non-volatile memory express drives (NVMe). Best practice is generally to use the latest BIOS version available for the server, even if it is newer than listed. Table 1. Check part details, parametric & specs updated 04 NOV 2023 and download pdf datasheet from datasheets. com, a global distributor of electronics components. Check part details, parametric & specs updated 14 AUG 2023 and download pdf datasheet from datasheets. com, a global distributor of electronics components.